藉由分光光度計與預製試劑進行廢水苯酚分析Phenol Analysis
Low Range Phenol Analysis
0.05 to 5.0 mg/L Phenol using TNT868 (Utilizing 5-cm sample cuvette)
USEPA 4-Aminoantipyrine Method (USEPA method 420.1 for wastewater)
![]() |
The standard concentration ranges for the TNT868 phenol reagent is 5 to 40 mg/L and 20 to 150 mg/L. For some applications and sample types, lower phenol concentration ranges are needed. By following this application note, the analyst can get down to 50 µg/L (part per billion). If the samples need to be distilled, follow this application note (LIT2224). For more information on this application, see Method 10266 (DOC316.53.01496). |
Application Notes | Type | Language | Size | Date | Edition |
---|---|---|---|---|---|
Low Range Phenol Analysis: 0.05 to 5.0 mg/L Phenol using TNT868 (Utilizing 5-cm sample cuvette) DOC042.53.20228 |
English US | 503 KB | 2016-08 | Mar16 |