線上水中溶氧感測器 Orbisphere A1100 Oxygen EC Sensors
產品編號:
The ORBISPHERE A1100 oxygen (O2) sensor is the latest development of the well-known and proven ORBISPHERE Electro-Chemical (EC) sensors.
A1100傳感器應用範圍極廣, 從製程監測到實驗室分析, 從啤酒或飲料生產到半導體晶片製造, 核電廠反應爐冷卻系統,提供氧氣精確檢測。
Ideal for Harsh Environments
Simple Installation and Operation
Low Maintenance
Easy Calibration
Uncomplicated Data Management
A1100傳感器應用範圍極廣, 從製程監測到實驗室分析, 從啤酒或飲料生產到半導體晶片製造, 核電廠反應爐冷卻系統,提供氧氣精確檢測。
Ideal for Harsh Environments
Simple Installation and Operation
Low Maintenance
Easy Calibration
Uncomplicated Data Management
This sensor is designed for process monitoring as well as laboratory analysis in the liquid or gas phases across a wide range of applications from beer or soft-drinks production to rinsing of semiconductor wafers in chip-manufacturing plants, reactor coolant systems in nuclear power plants, or any place where oxygen measurement is critical. Unrivalled accuracy and response time for fast detection of process change.
The unique design of the ORBISPHERE sensor allows for extended periods between recharges. Sensor refurbishment in 3 minutes with pre-filled recharge cartridge.* (*patent-pending)
Ideal for Harsh Environments
The Hach Orbisphere 3650 Oxygen Analyzer 可攜式氧/溶氧分析儀 offers a robust portable system solution for oxygen measurement. The compact stainless steel construction is designed for the harsh environment of breweries, but it is also perfectly adapted for laboratory or verification purposes in other beverage applications. In addition, the 3650 can be used across a wide range of applications in the power generation, electronics and life sciences industries. Designed for use with the Orbisphere A1100 high quality oxygen sensor, these instruments provide fast, accurate and repeatable measurements in both the dissolved and gaseous phase, at line or in the laboratory.
For low level applications, the specially configured Orbisphere 3655 measures to 0.1 ppb oxygen.
Simple Installation and Operation
The Orbisphere 3650 inlet tube is connected to a sample point or to a piercing device by a simple connector, making it quick and easy to install. The sample flows over the sensor membrane in the flow chamber, with an output valve controlling the sample's flow rate. The instrument's outlet tube allows the sample to drain away. The sample volume requirement is small, minimizing waste. The Orbisphere 3650 uses two C-type, NiMH or alkaline batteries. Changing the batteries is quick and easy; there is no down time for the instrument. Stored measurements are not lost if batteries go flat or are being changed.
Low Maintenance
The use of the Orbisphere A1100 sensor with this portable instrument allows for very quick cleaning with nothing more than tap water and requires no technical skills. The sensor refurbishment (typically every 6 months) takes only 3 minutes with a pre-mounted membrane cartridge and electrolyte, eliminating any risk of incorrect membrane positioning.
Easy Calibration
Calibration after each sensor refurbishment is recommended. A traceable and simple calibration can be done directly in air by measuring its oxygen content with the use of the built-in pressure sensor and the automatic software calculation. Alternatively, the calibration can be performed against a liquid or gaseous sample of known concentration by simply entering the gas concentration via the keyboard. The Orbisphere A1100 oxygen sensor technology reduces residual signals to negligible levels, eliminating the need for a zero point calibration and providing fast response times essential for multiple measurements. A number of different membranes are available for use with the sensor, optimizing the wide range of measurement applications.
Uncomplicated Data Management
The Orbisphere 3650 display is large and easy to read. No conversion tables are needed as this instrument directly indicates the gas concentration in the chosen unit. The temperature of the sample is displayed by pressing one key. Each instrument comes with a Windows® software package that enables the user to analyze up to 500 stored measurements and to configure the instrument. Using the RS-232 connection, stored measurements can be simply downloaded to a PC for analysis.
Part Number
|
||||
---|---|---|---|---|
A1100-S00
|
Range at 25 °C -5 – 95 °C 2935A-A : 10 ppb–400 ppm or 20 Pa–1,000 kPa 2952A-A : 1 ppb–80 ppm or 5 Pa–200 kPa 2956A-A : 0.1 ppb–20 ppm or 0.25 Pa–50 kPa 29552A-A : 2 ppb–80 ppm or 5 Pa–200 kPa |
±1% of reading, or ± lower measurement range, whichever is greater ±1% of reading, or ± lower range, whichever is greater (Assuming correct calibration) |
Stainless Steel 1.4404 (AISI 316L), surface finish: N5, Ra < 0.4 µm Membrane (see specification table). No O-rings are in contact with the sample. |
0 – 100 |
A1100-S00T
|
Range at 25 °C 2935A-A : 10 ppb–400 ppm or 20 Pa–1,000 kPa 2952A-A : 1 ppb–80 ppm or 5 Pa–200 kPa 2956A-A : 0.1 ppb–20 ppm or 0.25 Pa–50 kPa 29552A-A : 2 ppb–80 ppm or 5 Pa–200 kPa |
±1% of reading, or ± lower measurement range, whichever is greater |
Stainless Steel 1.4404 (AISI 316L), surface finish: N5, Ra < 0.4 µm Membrane (see specification table). No O-rings are in contact with the sample. |
0 – 100 |
A1100-S0S
|
Range at 25 °C 2935A-A : 10 ppb–400 ppm or 20 Pa–1,000 kPa 2952A-A : 1 ppb–80 ppm or 5 Pa–200 kPa 2956A-A : 0.1 ppb–20 ppm or 0.25 Pa–50 kPa 29552A-A : 2 ppb–80 ppm or 5 Pa–200 kPa |
±1% of reading, or ± lower measurement range, whichever is greater |
Stainless Steel 1.4404 (AISI 316L), surface finish: N5, Ra < 0.4 µm Membrane (see specification table). No O-rings are in contact with the sample. |
0 – 100 |
Datasheets/Brochures | Type | Language | Size | Date | Edition |
---|---|---|---|---|---|
CALIDAD DEL AGUA GARANTIZADA Para todo el mundo DOC030.61.10116 |
Spanish | 553 KB | 2016-11 | Sep16 | |
ENSURING WATER QUALITY For people around the world DOC030.53.10116 |
English US | 553 KB | 2016-11 | Sep16 | |
GARANTIR LA QUALITÉ DE L’EAU Pour les habitants du monde entier DOC030.77.10116 |
French | 554 KB | 2016-11 | Sep16 | |
Hach Orbisphere A1100 Data Sheet LIT2663 |
English US | 67 KB | 2010-02 | Rev 1 | |
PULP & PAPER INDUSTRY DOC030.53.10119 |
English US | 1593 KB | 2017-03 | Feb17 | |
Главное - точность: кислородный датчик ORBISPHERE A1100 DOC063.62.30042 |
Russian | 843 KB | 2011-10 |
Manuals | Type | Language | Size | Date | Edition |
---|---|---|---|---|---|
Basic User Manual: ORBISPHERE A1100 Family of Oxygen Electrochemical Sensors DOC024.98.93018 |
English UK, German, Italian, French, Spanish, Danish, Dutch | 7191 KB | 2015-05 | Ed 1 | |
Basic User Manual: ORBISPHERE Model 32301 Sensor Cleaning and Regeneration Center DOC024.98.93013 |
English UK, German, Finnish, Russian | 1165 KB | 2017-01 | Jan17 Ed5 | |
ORBISPHERE A1100, capteur électrochimiques d'oxygène-MANUEL DE L'UTILISATEUR DGA1100-MAN/F |
French | 747 KB | 2009-10 | Rev D | |
ORBISPHERE A1100-EC-Sauerstoffsensor Installation und Wartung Bedienerhandbuch | German | 1083 KB | 2008-05 | Rev B | |
ORBISPHERE A1100 Oxygen Electrochemical Sensors-User Manual DGA1100-MAN/E |
English US | 5448 KB | 2009-10 | Rev E | |
User Manual: ORBISPHERE A1100 Family of Oxygen Electrochemical Sensors DOC024.52.93018 |
English UK | 6782 KB | 2015-05 | Ed 6 |
影片>Orbisphere A1100 氧氣傳感器 設定篇 (點圖觀看)