Only two liters of reagent are required for the analyzer to perform unattended for up to 90 days. The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps. Predictive diagnostic tools, including Hach's proprietary Prognosys technology, warning LEDs, and high-visibility notification screens let you avoid unplanned downtime. No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently. Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test. 只需兩公升試劑,9611 sc 分析儀即可在無人值守的情況下運作長達 90 天。
Measuring principle 量測原理 : Colorimetric 比色法
Measuring range 量測範圍 :
LR model 低濃度 : 4 - 3000 µg/L as PO4 [Detection range capable of 4 - 5000 µg/L as PO4]
HR model 高濃度 : 200 - 50000 µg/L as PO4
Detection limit 偵測限 : LR model: 4 µg/L ; HR model: 200 µg/L
Grab sample 水樣獲取 : Grab Sample In and Grab Sample Out capability
Light source 光源 : Class 1M LED (light emitting diode) with a peak wavelength of 810 nm
Repeatability 重複性 :
LR model 低濃度 : ±1%
HR model 高濃度 : ±500 µg/L or ±5% of reading, whichever is greater
Response time 反應時間:Typically, 9 minutes at 25 °C; changes with temperature
Sample pressure : 0.14 - 6 bar (to preset pressure regulator)
Outputs 輸出 : 4 - 20 mA
Certifications 認證 : CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000)
KC (EN 61326-1: 2006)
C-tick (EN 61326-1: 2006)
cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
可用Hach實驗室產品進行驗證,不需浪費時間進行二次猜測,進樣(Grab-in)和取樣(Grab-out)功能可快速將外部欲分析水樣倒入分析儀內,同時也便於從分析儀中取出水樣,帶回實驗室進行比對測試。
關鍵字 : 水 磷酸鹽 濃度 監測, 水 總磷 自動分析儀, 水 總磷濃度 連續監測, PO4 Analyzer
Measuring principle 量測原理 : Colorimetric 比色法
Measuring range 量測範圍 :
LR model 低濃度 : 4 - 3000 µg/L as PO4 [Detection range capable of 4 - 5000 µg/L as PO4]
HR model 高濃度 : 200 - 50000 µg/L as PO4
Detection limit 偵測限 : LR model: 4 µg/L ; HR model: 200 µg/L
Grab sample 水樣獲取 : Grab Sample In and Grab Sample Out capability
Light source 光源 : Class 1M LED (light emitting diode) with a peak wavelength of 810 nm
Repeatability 重複性 :
LR model 低濃度 : ±1%
HR model 高濃度 : ±500 µg/L or ±5% of reading, whichever is greater
Response time 反應時間:Typically, 9 minutes at 25 °C; changes with temperature
Sample pressure : 0.14 - 6 bar (to preset pressure regulator)
Outputs 輸出 : 4 - 20 mA
Certifications 認證 : CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000)
KC (EN 61326-1: 2006)
C-tick (EN 61326-1: 2006)
cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
可用Hach實驗室產品進行驗證,不需浪費時間進行二次猜測,進樣(Grab-in)和取樣(Grab-out)功能可快速將外部欲分析水樣倒入分析儀內,同時也便於從分析儀中取出水樣,帶回實驗室進行比對測試。
關鍵字 : 水 磷酸鹽 濃度 監測, 水 總磷 自動分析儀, 水 總磷濃度 連續監測, PO4 Analyzer
Low maintenance 低維護量
提供可靠的測量結果,並幫助您節省維護時間和精力。
提供可靠的測量結果,並幫助您節省維護時間和精力。
Reduced downtime 低停機率
User-defined reagents that meet individual needs
90 days of continuous runtime 90天持續運作
分析儀只需要兩升的試劑就可以實現無人輪值看守長達 90 天。
分析儀只需要兩升的試劑就可以實現無人輪值看守長達 90 天。
Easily verified with our lab products - no time wasted by second-guessing
適用於Polymetron 9610/9611的 PROGNOSYS™ 軟體診斷系統 |
避免意料之外的緊急維護
PROGNOSYS 為一款預先診斷系統,該系統能夠針對儀器未來將出現的問題預先發出提示和警告,便於您對維護作業進行前瞻性安排。當儀器或水體發生變化時,透過該系統,即可確保您對測量結果的變化作出胸有成竹的判斷。
|
測量標識
用於監測儀器各個零件,並可在測量出現問題前,向用戶發出儀器未來需求的警示消息
|
維護標識
用於追踪儀器需要維護或檢修的剩餘天數
|
需立即維護 | 有待維護 | 理想性能狀態 |
測量標識:
校正斜率超出可接受限值
樣本需要很高的光能
讀取樣本數據期間,檢出強光
檢出樣本質量差
|
測量標識:
校正結果接近可接受限值
樣本需要的光能超出預期
讀取樣本期間發生高曝光
檢出樣本質量存在問題
|
測量標識:
校正結果處於可接受限值範圍內
所需光能在合理範圍內
讀取樣本期間未檢出曝光或曝光量很低
可準確讀取受測樣本
|
維護標識:
過濾器,閥門,管道和其他磨損零件需要立即維護
|
維護標識:
過濾器,閥門,管道和其他磨損零件需要在90天內進行預期維護
|
維護標識:
未來90天內不存在針對過濾器,閥門,管道和其他磨損零件的維護作業
|
Prognosys操作原理
Prognosys預先診斷功能是一款內建於Polymetron 9610矽表和Polymetron 9611磷表的預先診斷模組,可確保用戶對維護工作的前瞻性安排。該功能透過對儀器內部零件的監測以及檢修要求的追踪,對即將到來的維護任務發出提醒,讓用戶對儀器及其檢測結果充滿信心。
Prognosys預先診斷功能透過測量標識和維護標識提供關於預防性維護的必要信息。維護標識通過追踪需要各項維護指標的剩餘天數來推斷未來維護任務,使維護工作變得簡單。測量標識不僅能夠追踪預期維護工作,而且還能夠對儀器的內部信號進行解讀,以便用戶了解儀器的當前狀況,確保在檢測結果出問題且可能影響工作進程之前,讓用戶了解儀器所需要進行的維護工作。讀數以百分比的方式表示。
|