水中氨氮試劑(超高濃度) Ammonia TNTplus vial test, UHR (47-130 mg/L NH3-N)
產品編號:TNT833
超高量測範圍水中氨氮分析試劑TNT833適用於廢污水、化工、食品產業領域的水質分析。
For determination of Ammonia Nitrogen by the Salicylate Method. EPA compliant. 水楊酸方法檢測水中氨氮濃度. 符合美國環保署核定測試方法.
*使用 Hach DR3900, DR6000, DR1900, DR2800, DR3800 及 DR5000 分光光度計進行分析 (使用前需確認軟體版本並視需要更新軟體)。
Expert Ultra High Range Ammonia Test Made Simple
預製型水中氨氮試劑TNT833幫助您快速專業簡單分析超高濃度氨氮
快速, 簡易, 安全, 方便識別之條碼瓶身 專業貼心設計
Ammonia Nitrogen TNTplus™ chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime.
Method : 10205
Method Name : Salicylate
Parameter : Ammonia, Nitrogen
Range : 47 - 130 mg/L NH₃-N
關鍵字 : 水 氨氮濃度 測定, 水中 氨氮 測試, 廢污水 氨氮濃度 分析
For determination of Ammonia Nitrogen by the Salicylate Method. EPA compliant. 水楊酸方法檢測水中氨氮濃度. 符合美國環保署核定測試方法.
*使用 Hach DR3900, DR6000, DR1900, DR2800, DR3800 及 DR5000 分光光度計進行分析 (使用前需確認軟體版本並視需要更新軟體)。
Expert Ultra High Range Ammonia Test Made Simple
預製型水中氨氮試劑TNT833幫助您快速專業簡單分析超高濃度氨氮
快速, 簡易, 安全, 方便識別之條碼瓶身 專業貼心設計
Ammonia Nitrogen TNTplus™ chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime.
Method : 10205
Method Name : Salicylate
Parameter : Ammonia, Nitrogen
Range : 47 - 130 mg/L NH₃-N
關鍵字 : 水 氨氮濃度 測定, 水中 氨氮 測試, 廢污水 氨氮濃度 分析
Easy and safe handling
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
No reagent blank necessary
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
Documented shelf life and COA
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.