電感式水中導電度線上感測器 Analog Electrodeless Conductivity Sensor, Convertible Style, PVDF Body Material, Small Bore Electrode SNS, 50 ft Cable
產品編號:3726E2T50N
PVDF, Convertible Mounting Style, 15m (50 ft) Analog Cable, Stainless Steel Tag, Electrodeless Conductivity Sensor
Range 量測範圍 : 200 µS/cm - 2000000 mS/cm
Sensor Type 感測器種類 : Analog
Applications 應用 :
Membrane Protection
Nutrient Monitoring
Secondary Treatment
Ultrapure Water
關鍵字 : 線上 水中導電度計, 水中 導電度 連續監測, 水中導電度 線上分析儀
Range 量測範圍 : 200 µS/cm - 2000000 mS/cm
Sensor Type 感測器種類 : Analog
Applications 應用 :
Membrane Protection
Nutrient Monitoring
Secondary Treatment
Ultrapure Water
關鍵字 : 線上 水中導電度計, 水中 導電度 連續監測, 水中導電度 線上分析儀
Wide Measuring Range 量測範圍寬廣
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Low Maintenance Design 電感式導電度感測技術 減低日常維護工作量
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
Versatile Mounting Styles 靈活安裝方式
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Principal of Operation
Inductive conductivity sensors induce a low current in a closed loop of solution, then measure the magnitude of this current to determine the solution’s conductivity. The conductivity analyzer drives Toroid A, inducing an alternating current in the solution. This current signal flows in a closed loop through the sensor bore and surrounding solution. Toroid B senses the magnitude of the induced current which is proportional to the conductance of the solution. The analyzer processes this signal and displays the corresponding reading.
Inductive conductivity sensors induce a low current in a closed loop of solution, then measure the magnitude of this current to determine the solution’s conductivity. The conductivity analyzer drives Toroid A, inducing an alternating current in the solution. This current signal flows in a closed loop through the sensor bore and surrounding solution. Toroid B senses the magnitude of the induced current which is proportional to the conductance of the solution. The analyzer processes this signal and displays the corresponding reading.
Withstands Harsh Environments 耐受嚴苛環境
The inductive sensor is available in sanitary (CIP) flange style and convertible styles in PFA®, polypropylene, PEEK®, and PVDF material. Select sensors can withstand high pressures and temperatures.
The inductive sensor is available in sanitary (CIP) flange style and convertible styles in PFA®, polypropylene, PEEK®, and PVDF material. Select sensors can withstand high pressures and temperatures.
Specifications