水中氯離子分析電極 Intellical™ ISECL181 Chloride (Cl-) Ion Selective Electrode (ISE), 1m or 3m cable
產品編號:ISECL18101, ISECL18103
Hach ISECL181數位複合式水質分析電極適用於測量廢污水,飲用水和一般水質之氯化物濃度。
IntelliCALⓇ ISECL181 is a digital, combination, Chloride ion selective electrode (ISE) with a with a non-refillable gel driTEK reference with a double junction, ceramic porous pin and porous PTFE annular ring, and built-in temperature sensor. The electrode measures Chloride concentration in water samples. The laboratory version of this ISE is shockproof with its Epoxy plastic body.The IntelliCAL ISECL181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications.
ISECL181 的固態感測器設計無需更換薄膜,ISE 能夠乾燥儲存。
測試方法 Method : 10255 Direct Measurement Powder Pillow ISA
量測範圍 Range : 3.55 - 35 g/L Cl-
*使用Hach HQ系列主機進行分析
關鍵字 : 水中 氯化物 濃度 檢測 探頭
IntelliCALⓇ ISECL181 is a digital, combination, Chloride ion selective electrode (ISE) with a with a non-refillable gel driTEK reference with a double junction, ceramic porous pin and porous PTFE annular ring, and built-in temperature sensor. The electrode measures Chloride concentration in water samples. The laboratory version of this ISE is shockproof with its Epoxy plastic body.The IntelliCAL ISECL181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications.
ISECL181 的固態感測器設計無需更換薄膜,ISE 能夠乾燥儲存。
測試方法 Method : 10255 Direct Measurement Powder Pillow ISA
量測範圍 Range : 3.55 - 35 g/L Cl-
*使用Hach HQ系列主機進行分析
關鍵字 : 水中 氯化物 濃度 檢測 探頭
Requires virtually no maintenance
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
Fast, stable, and accurate results
Intellical digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
Intellical digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
Ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
Can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters