水中pH分析電極 IntelliCAL™ PHC101 Rugged Gel Filled pH Electrode
產品編號:
Intelligent HQD Intellical Probe
IntelliCAL™ PHC101 is a digital, combination pH probe with a non-refillable, gel-filled single-junction reference and built-in temperature sensor. The rugged version is available with a 5, 10, 15, or 30 meter cable and is intended for field use. The PHC101 is ideal for measuring pH in wastewater applications.
*IntelliCAL™ Rugged digital probes can reliably test in the harshest environmental conditions
*IntelliCAL™ digital probes provide ultimate traceability in measurement history
*IntelliCAL™ digital probes alert the user when re-calibration is needed
*IntelliCAL™ digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings
*IntelliCAL™ rugged digital probes are waterproof up to 30 meters (IP68 rating)
Hach HQd 系列便攜式水質分析儀目前可檢測多種參數。Hach HQd便攜式水質分析儀具有絕佳測量靈活性,電極更換等操作簡單,可自動識別電極。
HQd系列多參數水質檢測儀包含各種IntelliCALTM 電極,可測量pH、導電度、溶氧(LDO),LBOD,ORP 以及鈉、銨、氨、氟、硝酸鹽、氯等多項水質參數。
關鍵字 : pH Meter, pH probe, 水 pH 探頭
IntelliCAL™ PHC101 is a digital, combination pH probe with a non-refillable, gel-filled single-junction reference and built-in temperature sensor. The rugged version is available with a 5, 10, 15, or 30 meter cable and is intended for field use. The PHC101 is ideal for measuring pH in wastewater applications.
*IntelliCAL™ Rugged digital probes can reliably test in the harshest environmental conditions
*IntelliCAL™ digital probes provide ultimate traceability in measurement history
*IntelliCAL™ digital probes alert the user when re-calibration is needed
*IntelliCAL™ digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings
*IntelliCAL™ rugged digital probes are waterproof up to 30 meters (IP68 rating)
Hach HQd 系列便攜式水質分析儀目前可檢測多種參數。Hach HQd便攜式水質分析儀具有絕佳測量靈活性,電極更換等操作簡單,可自動識別電極。
HQd系列多參數水質檢測儀包含各種IntelliCALTM 電極,可測量pH、導電度、溶氧(LDO),LBOD,ORP 以及鈉、銨、氨、氟、硝酸鹽、氯等多項水質參數。
關鍵字 : pH Meter, pH probe, 水 pH 探頭
IntelliCAL™ Rugged digital probes can reliably test in the harshest environmental conditions
Stainless steel body, polymer sensor shroud, and reinforced, steel-sheathed cables protect the probe for measurement anywhere in the field.
IntelliCAL™ digital probes provide ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
IntelliCAL™ digital probes alert the user when re-calibration is needed
No guesswork needed to provide the most reliable and accurate results with each measurement.
IntelliCAL™ digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQd series Laboratory and Portable meters.
IntelliCAL™ rugged digital probes are waterproof up to 30 meters (IP68 rating)
pH | Method | Range | Reagent Set(s) | USEPA Compliant? |
---|---|---|---|---|
8156 pH Meter Electrode Method | 2.00 - 14.00 pH | Y |
Application Notes | Language | Size | Date | Edition |
---|---|---|---|---|
Application Note: Learn how to really clean pH probes from individual sample contamination to maintain best performance of your pH probes. DOC042.98.20172 |
German, English UK | 290 KB | 2014-09 | Sep14 |
Data Sheet: HQd pH Electrode Cleaning and Maintenance Guide LIT2781 |
English US | 532 KB | 2014-02 | Rev 1 |
Electrochemistry Theory and Practice White Paper: pH Electrochemistry |
English US | 320 KB | 2011-02 | |
Poster: Cleaning and maintenance of pH probes DOC142.52.20158 |
English UK | 648 KB | 2016-09 | Sep16 |
Technical note pH measurement system DOC42.52.20152 |
English UK | 183 KB | 2013-11 | |
Technical Note pH Trace Analysis (en) DOC042.52.20150 |
English UK | 95 KB | 2013-11 | |
Temperature Compensation with pH Measurement LIT2007 |
English US | 524 KB | 2013-08 | Ed1 |
What are the individual parts of a pH electrode? DOC042.52.20151 |
English UK | 79 KB | 2013-11 | Nov13 |
Datasheets/Brochures | Language | Size | Date | Edition |
---|---|---|---|---|
Complete Water Analysis Solutions for POWER GENERATION DOC030.53.10024 |
English US | 1 MB | 2016-10 | Mar16 |
Hach Laboratory Quick Guide for Power Applications DOC062.53.20210 |
English US | 578 KB | 2015-11 | Nov15 |
HQD Digital Meters and Intellical™ Probes Data Sheet LIT2599 |
English US | 755 KB | 2016-06 | Rev8 |
The best solution for accurate results in all applications - HQD meters and high performance pH electrodes DOC032.53.20163 |
English US | 328 KB | 2015-08 | Aug15 |
Manuals | Language | Size | Date | Edition |
---|---|---|---|---|
Basic User Manual for PHC101 Probes DOC022.97.80023 |
English US, French, Spanish, Portuguese, Chinese, Japanese, Korean, Thai | 932 KB | 2013-05 | Ed 2 |
User Manual for PHC101 Probes DOC022.53.80023 |
English US | 359 KB | 2013-05 | Ed 2 |
Methods/Procedures | Language | Size | Date | Edition |
---|---|---|---|---|
Hydraulic Fracturing Procedures Water Analysis Handbook for use with DR 900 DOC022.53.80225 |
English US | 2 MB | 2017-01 | Ed 8 |
pH, Electrode Method 8156, pH Meter DOC316.53.01245 |
English US | 223 KB | 2015-03 | Ed 8 |