手持式水質檢測比色計 DR300 Pocket Colorimeter
產品編號
適用環境:飲用水、污水、電力、食品飲料、工業等

檢測參數 : 餘氯/總氯、溴、硝酸鹽、溶氧、臭氧、磷酸鹽、二氧化氯、鋅、鉬、氯/pH值、錳、鐵(TPTZ法)、鐵(FerroVer法)、鋁、一氯胺/游離氨、氨氮

全新攜帶型比色計DR300全方面提升,IP67防水等級和堅固設計;人體工學設計; 升級為更大的顯示螢幕和更亮的背光、讀值更清晰。即便在複雜的測量環境,使用者仍擁有良好的客戶體驗和精確可靠的測量。

簡單、直覺式的操作減少潛在的人為操作失誤,讓測量更精確,資料在任何時候都可靠。

DR300攜帶型比色計不僅適用於戶外現場水質測試,也適用於實驗室內的水質分析。

此外,您還可透過選配之HACH通訊適配器,與手機和雲服務相連。可以讓資料無縫傳輸到手機和Claros - Hach智慧系統之上,實現資料的無線傳輸和智慧管理,效率事倍功半。

*說明:目前藍牙連接功能和Claros系統僅於美國, 加拿大及歐盟區域銷售

關鍵字 : 攜帶式水質檢測儀器, 手持 餘氯總氯測定計, 手持 磷酸鹽測定計, 手持 鋁測定計, 移動式 水質檢測設備, 簡易水質檢測儀, 比色儀, PCII 比色計
產品介紹
Aluminum Method Range Reagent Set(s) USEPA Compliant?
  8012 Aluminon Method, Powder Pillows 0.02 - 0.80 mg/L Al₃+ View  
Ammonia Method Range Reagent Set(s) USEPA Compliant?
  8155 Powder Pillows 0.01 - 0.80 mg/L NH₃-N View  
Ammonia, Free Method Range Reagent Set(s) USEPA Compliant?
  10200 Chloramine (Mono) and Nitrogen, Free Ammonia Powder Pillows, Pocket Colorimeter II 0.02 - 0.50 mg/L NH₃-N View  
Bromine Method Range Reagent Set(s) USEPA Compliant?
  8016 DPD, PP or AccuVac DR300 PCII 0.05 - 4.50 mg/L Br₂ View  
  8016 Pocket Colorimeter DR300 0.2 - 10.0 mg/L Br₂ View  
Chlorine Dioxide Method Range Reagent Set(s) USEPA Compliant?
  10126 DR300 PCII DPD Powder Pillows 0.05 - 5.00 mg/L ClO₂ View  
Chlorine, Free Method Range Reagent Set(s) USEPA Compliant?
  8021 DPD PCII DR300 SwifTest Dispenser 0.02 - 2.00 mg/L Cl2 View  
  DPD PCII DR300 SwifTest Dispenser 0.1 - 8.0 mg/L Cl2 View  
Chlorine, Free & Total Method Range Reagent Set(s) USEPA Compliant?
  PCII DR300 USEPA DPD, Mid-Range 0.05 - 4.00 mg/L Cl₂ View  
  Pocket Colorimeter DPD, High Range 0.1 - 8.0 DPD 0.1 - 8.0 mg/L Cl₂ View Y
  Pocket Colorimeter DPD, High Range 0.1-10 0.1 - 10 mg/L Cl₂ View  
  Pocket Colorimeter DPD, Low Range DPD 0.02 - 2.00 mg/L Cl₂   Y
Chlorine, Total Method Range Reagent Set(s) USEPA Compliant?
  8167 PCII DR300 DPD SwifTest Dispenser 0.02 - 2.00 mg/L Cl₂ View  
  DPD HR PCII DR300 SwifTest Dispenser 0.1 - 8.0 mg/L Cl2 View  
Dissolved Oxygen Method Range Reagent Set(s) USEPA Compliant?
  8166 DR300 PCII AccuVac 0.2 - 10.0 mg/L O2    
Iron Method Range Reagent Set(s) USEPA Compliant?
  8008 PCII DR300 Powder Pillows AccuVac 0.02 - 5.00 mg/L Fe View  
  8112 PCII DR300 Powder Pillows AccuVac 0.01 - 1.70 mg/L Fe View  
Manganese Method Range Reagent Set(s) USEPA Compliant?
  8034 PCII DR300 Powder Pillows 0 - 20.0 mg/L Mn View  
Molybdenum Method Range Reagent Set(s) USEPA Compliant?
  8169 PCII DR300 Ternary Complex 0.02 - 3.00 mg/L Mo View  
  8169 Ternary Complex 0.1 - 12.0 mg/L Mo View  
Monochloramine Method Range Reagent Set(s) USEPA Compliant?
  10200 Chloramine (Mono) and Nitrogen, Free Ammonia Powder Pillows, Pocket Colorimeter II 0.04 - 4.50 mg/L Cl₂ View  
Nitrate Method Range Reagent Set(s) USEPA Compliant?
  8039 Powder Pillows or AccuVac 0.4 - 30.0 mg/L NO₃⁻-N    
Ozone Method Range Reagent Set(s) USEPA Compliant?
  8311 AccuVac® Pocket Colorimeter 0.01 - 0.75 mg/L O₃ MR    
Phosphonates Method Range Reagent Set(s) USEPA Compliant?
  8007 Powder Pillows DR300 PCII 1.0 - 125 mg/L PO₄³⁻ View  
Phosphorus Method Range Reagent Set(s) USEPA Compliant?
  8048 Pocket Colorimeter PhosVer 3 (Ascorbic Acid) Method 0.02 - 3.00 mg/L PO₄ View  
Zinc Method Range Reagent Set(s) USEPA Compliant?
  8009 Pocket Colorimeter II Zincon 0.02 - 3.00 mg/L Zn View Y
 
 
Manuals Language Size Date Edition
User Instruction: DR300 Communication Dongle 
DOC272.99.90639
English US, English UK 1 MB 2018-12 Dec18 Ed1
User Manual: DR300 
DOC022.97.90639
English US, Spanish, French, Portuguese, Chinese, Japanese, Korean, Thai 1 MB 2019-01 Dec18 Ed1
 
Proven past. Innovative future.
The DR300 maintains the Pocket Colorimeter legacy of reliability while providing state-of-the-art data transfer capability and connection to Claros*. Reduce data collection hassles, eliminate transcription errors, and ensure stronger compliance traceability.
Please note that reagents are not included in the kit and need to be purchased separately.
 
*Claros connectivity currently available only in US, Canada and EU.
 
Connected*
Optional Bluetooth connectivity allows you to safely transfer measurement data to your existing database or to Claros – Hach®’s Water Intelligence System – reducing errors and saving time by eliminating manual data entry.
 
Reliable
Rugged, waterproof (IP67) design withstands whatever conditions you encounter in the field (drops, extreme temperatures, rain and dirt) and still delivers years of dependable, accurate measurements.
 
Simple
Simple, intuitive operation reduces potential manual error, ensuring accurate measurement data you can trust, time after time. Larger display with improved backlight makes reading measurements in all conditions even easier.
 
Methods/Procedures Language Size Date Edition
Aluminum, Aluminon Methos 8012, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01441
English US 674 KB 2019-01 Ed 2
Bromine, High Range, DPD Method 8016, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01443
English US 415 KB 2019-01 Ed 2
Bromine, Low Range, DPD Method 8016, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01444
English US 496 KB 2019-01 Ed 2
Chloramine (Mono) and Nitrogen, Free Ammonia, Indophenol Method 10200, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01445
English US 523 KB 2019-01 Ed 3
Chlorine Dioxide, DPD Method, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01447
English US 490 KB 2019-01 Ed 2
Chlorine, Free and Total, High Range, DPD Method 10069 (free)/10070 (total), Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01490
English US 305 KB 2019-01 Ed 3
Chlorine, Free and Total, High Range, DPD Method, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01449
English US 443 KB 2019-01 Ed 6
Chlorine, Free and Total, Low Range, DPD Method 8021 (free)/8167 (total), AccuVac Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01450
English US 508 KB 2019-01 Ed 4
Chlorine, Free and Total, Mid-Range, DPD Method 10245 (free)/10250 (total), Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01451
English US 428 KB 2019-01 Ed 2
Chlorine, Free, High Range, DPD Method, SwifTest Dispenser, DR300 and Pocket Colorimeter II 
DOC316.53.01488
English US 292 KB 2019-01 Ed 3
Chlorine, Free, Low Range, DPD Method 8021, SwifTest Dispenser, DR300 and Pocket Colorimeter II 
DOC316.53.01486
English US 404 KB 2019-01 Ed 2
Chlorine, Total, High Range, DPD Method, SwifTest Dispenser, DR300 and Pocket Colorimeter II 
DOC316.53.01489
English US 417 KB 2019-01 Ed 3
Chlorine, Total, Low Range, DPD Method 8167, SwifTest Dispenser, DR300 and Pocket Colorimeter II 
DOC316.53.01487
English US 414 KB 2019-01 Ed 2
Dissolved Oxygen, HRDO Method 8166, HR AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01467
English US 452 KB 2019-01 Ed 2
Iron, Total TPTZ Method 8112, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01457
English US 475 KB 2019-01 Ed 2
Iron, Total, FerroVer® Method 8008 , Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01458
English US 496 KB 2019-01 Ed 2
Manganese, Periodate Oxidation Method 8034, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01460
English US 473 KB 2019-01 Ed 2
Molybdenum, High Range, Ternary Complex Method 8169, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01462
English US 502 KB 2019-01 Ed 2
Molybdenum, Low Range, Ternary Complex Method 8169, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01463
English US 494 KB 2019-01 Ed 2
Nitrate, HR Cadmium Reduction Method 8039, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01465
English US 504 KB 2019-01 Ed 2
Nitrogen, Ammonia-Salicylate Method 8155 Powder Pillows, DR300 andPocket Colorimeter II 
DOC316.53.01466
English US 496 KB 2019-01 Ed 3
Ozone, Indigo Method 8311, AccuVac® AmAccupuls, DR300 and Pocket Colorimeter II 
DOC316.53.01468
English US 383 KB 2019-01 Ed 2
Phosphonates, PhosVer® 3 with Persulfate UV Oxidation Method 8007, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01470
English US 542 KB 2019-01 Ed 2
Phosphorus, Reactive (Orthophosphate), PhosVer® 3 Method 8048, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II 
DOC316.53.01471
English US 499 KB 2019-01 Ed 3
Zinc, Zincon Method 8009, Powder Pillows, DR300 and Pocket Colorimeter II 
DOC316.53.01476
English US 506 KB 2019-01 Ed 2