3700 (無電極)水中導電度感測器 Electrodeless Conductivity Sensor, PEEK, Convertible Style, 20 ft. Cable, Paper Tag
產品編號:3727E2T20P
PEEK, Convertible Mounting Style, 6m (20ft) Analog Cable, Paper Tag, Electrodeless Conductivity Sensor 可轉換安裝方式,類比電纜,無電極導電度感測器
Sensor Type 感測器類別 : Analog 類比
Body Material 材質 : PEEK with Paper Tagging
Range 量測範圍 : 200 µS/cm - 2000000 mS/cm
Mounting 安裝方式 : Convertible
Applications 應用 :
Membrane Protection 膜保護
Nutrient Monitoring 污水營養物質監測
Secondary Treatment 二級處理
Ultrapure Water 超純水
*使用Hach SC系列 digital controllers 數位控制主機進行全功能監控 – 連接後即可使用
關鍵字 : 水中 導電度 線上分析儀, online conductivity analyzer,
Sensor Type 感測器類別 : Analog 類比
Body Material 材質 : PEEK with Paper Tagging
Range 量測範圍 : 200 µS/cm - 2000000 mS/cm
Mounting 安裝方式 : Convertible
Applications 應用 :
Membrane Protection 膜保護
Nutrient Monitoring 污水營養物質監測
Secondary Treatment 二級處理
Ultrapure Water 超純水
*使用Hach SC系列 digital controllers 數位控制主機進行全功能監控 – 連接後即可使用
關鍵字 : 水中 導電度 線上分析儀, online conductivity analyzer,
Wide Measuring Range 量測範圍寬廣
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Low Maintenance Design 電感式導電度感測器技術 – 相較於傳統導電度計 大幅減低日常維護工作
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
電感式感測器設計免除傳統接觸式電極型導電度感測器的極化和電極塗層問題
Versatile Mounting Styles 靈活安裝方式
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Principal of Operation
Inductive conductivity sensors induce a low current in a closed loop of solution, then measure the magnitude of this current to determine the solution’s conductivity. The conductivity analyzer drives Toroid A, inducing an alternating current in the solution. This current signal flows in a closed loop through the sensor bore and surrounding solution. Toroid B senses the magnitude of the induced current which is proportional to the conductance of the solution. The analyzer processes this signal and displays the corresponding reading.
Withstands Harsh Environments 耐受嚴苛環境
The inductive sensor is available in sanitary (CIP) flange style and convertible styles in PFA®, polypropylene, PEEK®, and PVDF material. Select sensors can withstand high pressures and temperatures.