水中氧化還原值感測器 Hach Online Process ORP Sensor - Clean Water Analog ORP Sensor
產品編號:RD1R5
The smart choice for accurate and reliable online process ORP measurement
Clean Water Online Process ORP Sensor - Platinum ORP Electrode, PPS Housing, Convertible Mount, 4.5m Cable, Analog Cable Connection
Electrode Material 探頭材質 : Platinum
Electrode Type 探頭種類 : General Purpose
Measuring Range ORP 量測 : -1500 - +1500 mV
Operating Temperature Range : -5 - 105 °C
Pressure Range : 0 - 6.9 bar (100 psi)
Sensor Type : Analog
Applications: Membrane Protection, Nutrient Monitoring, Secondary Treatment, Ultrapure Water
關鍵字 : 水中 氧化還原值線上分析儀
Clean Water Online Process ORP Sensor - Platinum ORP Electrode, PPS Housing, Convertible Mount, 4.5m Cable, Analog Cable Connection
Electrode Material 探頭材質 : Platinum
Electrode Type 探頭種類 : General Purpose
Measuring Range ORP 量測 : -1500 - +1500 mV
Operating Temperature Range : -5 - 105 °C
Pressure Range : 0 - 6.9 bar (100 psi)
Sensor Type : Analog
Applications: Membrane Protection, Nutrient Monitoring, Secondary Treatment, Ultrapure Water
關鍵字 : 水中 氧化還原值線上分析儀
Exceptional Performance with the Differential Electrode Measurement Technique 差分電極測量技術的卓越性能
This field-proven technique uses three electrodes instead of the two normally used in conventional ORP sensors. Process and reference electrodes measure the ORP differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
This field-proven technique uses three electrodes instead of the two normally used in conventional ORP sensors. Process and reference electrodes measure the ORP differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
Lower Maintenance Needs with the Double Junction Salt Bridge 雙結鹽橋降低維修需求
The double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
The double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
Extended Working Life with the Replaceable Salt Bridge/Protector 可更換鹽橋/保護器可延長使用壽命
The unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.
The unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.
Reliability with Built-in Encapsulated Preamp 內建封裝前置放大器的可靠性
Encapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analog sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyzer.
Encapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analog sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyzer.
Patented Technology 專利技術
The former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD™ sensor series (U.S. Patent Number 6395158B1, dated May 28, 2002) takes this field-proven technology to a new level.
The former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD™ sensor series (U.S. Patent Number 6395158B1, dated May 28, 2002) takes this field-proven technology to a new level.
Versatile Mounting Styles 多種靈活安裝方式
Sensors are available in four mounting styles—convertible, insertion, immersion, and sanitary.
Sensors are available in four mounting styles—convertible, insertion, immersion, and sanitary.