自動滴定儀 石化應用分析模組 : 總酸值 Titration Application Pack Petrochemistry: TAN (Total Acid Number)
產品編號AP0015.AT1102
Application Pack for the determination of the Total Acid Number in Petrochem.

Suited for TitraLab® AT1000 Series, Automatic Titrator Models AT1102/AT1112/AT1122/AT1222.
搭配 Hach 自動滴定儀 AT1102/AT1112/AT1122/AT1222 使用

AT1000 Total Acid Number (TAN) Titration Automatic Titrator Method
Range : 0.05 - 260 mg/L TAN

關鍵字 : 水 總酸值
產品介紹
Acid-Base Method Range Reagent Set(s) USEPA Compliant?
  AT1000 Total Acid Number (TAN) Titration Automatic Titrator Method 0.05 - 260 mg/L TAN View  
 
Application Notes Language Size Date Edition
Measuring Scale Forming Potential in Cooling Water 
DOC042.53.20252
English US 531 KB 2016-10 Oct16
Datasheets/Brochures Language Size Date Edition
Complete Water Analysis Solutions for POWER GENERATION 
DOC030.53.10024
English US 1 MB 2016-10 Mar16
HACH LABORATORY QUICK GUIDE FOR<br />FOOD APPLICATIONS 
DOC062.53.20231
English US 640 KB 2016-09 Apr16
Titralab AT1000 Series Automatic Titrators 
DOC052.53.25006
English US 993 KB 2015-09 Sep15
Methods/Procedures Language Size Date Edition
Total acid number (TAN), Potentiometric titration (ASTM D664) 
DOC316.52.93095
English UK 229 KB 2015-03  
Software/Firmware Language Size Date Edition
AT1102 Software update 
Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa.
In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well.
To Update a TitraLab 1000 Series Titrator: 
1. Connect a USB memory stick (FAT32) into the USB port of your PC. 
2. Click the link above and unzip the files.
3. Review “Software Update Procedure”.
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish 5 MB 2017-07 v1.23
AT1112 Software update 
Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa.
In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well.
To Update a TitraLab 1000 Series Titrator: 
1. Connect a USB memory stick (FAT32) into the USB port of your PC. 
2. Click the link above and unzip the files.
3. Review “Software Update Procedure”.
English US, English UK, Chinese, French, German, Italian, Japanese, Portuguese, Spanish 5 MB 2017-07 v1.23
AT1122 Software update 
Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa.
In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well.
To Update a TitraLab 1000 Series Titrator: 
1. Connect a USB memory stick (FAT32) into the USB port of your PC. 
2. Click the link above and unzip the files.
3. Review “Software Update Procedure”.
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish 5 MB 2017-07 v1.23
AT1222 Software update 
Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa.
In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well.
To Update a TitraLab 1000 Series Titrator: 
1. Connect a USB memory stick (FAT32) into the USB port of your PC. 
2. Click the link above and unzip the files.
3. Review “Software Update Procedure”.
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish 5 MB 2017-07 v1.23
TM1000 Update Installed Version 
Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa.
In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well.
See “Readme.txt” file for install instructions
Spanish, Italian, German, French, English US, English UK 136 MB 2017-07 V1.13