自動滴定儀 石化應用分析模組 : 總酸值 Titration Application Pack Petrochemistry: TAN (Total Acid Number)
產品編號:AP0015.AT1102
Application Pack for the determination of the Total Acid Number in Petrochem.
Suited for TitraLab® AT1000 Series, Automatic Titrator Models AT1102/AT1112/AT1122/AT1222.
搭配 Hach 自動滴定儀 AT1102/AT1112/AT1122/AT1222 使用
AT1000 Total Acid Number (TAN) Titration Automatic Titrator Method
Range : 0.05 - 260 mg/L TAN
關鍵字 : 水 總酸值
Suited for TitraLab® AT1000 Series, Automatic Titrator Models AT1102/AT1112/AT1122/AT1222.
搭配 Hach 自動滴定儀 AT1102/AT1112/AT1122/AT1222 使用
AT1000 Total Acid Number (TAN) Titration Automatic Titrator Method
Range : 0.05 - 260 mg/L TAN
關鍵字 : 水 總酸值
Acid-Base | Method | Range | Reagent Set(s) | USEPA Compliant? |
---|---|---|---|---|
AT1000 Total Acid Number (TAN) Titration Automatic Titrator Method | 0.05 - 260 mg/L TAN | View |
Application Notes | Language | Size | Date | Edition |
---|---|---|---|---|
Measuring Scale Forming Potential in Cooling Water DOC042.53.20252 |
English US | 531 KB | 2016-10 | Oct16 |
Datasheets/Brochures | Language | Size | Date | Edition |
---|---|---|---|---|
Complete Water Analysis Solutions for POWER GENERATION DOC030.53.10024 |
English US | 1 MB | 2016-10 | Mar16 |
HACH LABORATORY QUICK GUIDE FOR<br />FOOD APPLICATIONS DOC062.53.20231 |
English US | 640 KB | 2016-09 | Apr16 |
Titralab AT1000 Series Automatic Titrators DOC052.53.25006 |
English US | 993 KB | 2015-09 | Sep15 |
Methods/Procedures | Language | Size | Date | Edition |
---|---|---|---|---|
Total acid number (TAN), Potentiometric titration (ASTM D664) DOC316.52.93095 |
English UK | 229 KB | 2015-03 |
Software/Firmware | Language | Size | Date | Edition |
---|---|---|---|---|
AT1102 Software update Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa. In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well. To Update a TitraLab 1000 Series Titrator: 1. Connect a USB memory stick (FAT32) into the USB port of your PC. 2. Click the link above and unzip the files. 3. Review “Software Update Procedure”. |
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish | 5 MB | 2017-07 | v1.23 |
AT1112 Software update Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa. In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well. To Update a TitraLab 1000 Series Titrator: 1. Connect a USB memory stick (FAT32) into the USB port of your PC. 2. Click the link above and unzip the files. 3. Review “Software Update Procedure”. |
English US, English UK, Chinese, French, German, Italian, Japanese, Portuguese, Spanish | 5 MB | 2017-07 | v1.23 |
AT1122 Software update Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa. In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well. To Update a TitraLab 1000 Series Titrator: 1. Connect a USB memory stick (FAT32) into the USB port of your PC. 2. Click the link above and unzip the files. 3. Review “Software Update Procedure”. |
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish | 5 MB | 2017-07 | v1.23 |
AT1222 Software update Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa. In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well. To Update a TitraLab 1000 Series Titrator: 1. Connect a USB memory stick (FAT32) into the USB port of your PC. 2. Click the link above and unzip the files. 3. Review “Software Update Procedure”. |
English US, Chinese, English UK, French, German, Italian, Japanese, Portuguese, Spanish | 5 MB | 2017-07 | v1.23 |
TM1000 Update Installed Version Please NOTE: TM1000 PC software update requires an AT1000 firmware update and vice versa. In case of stirrer control issues an AT1000 firmware update is recommended. If TM1000 PC software is used an update is recommended as well. See “Readme.txt” file for install instructions |