水中鉻自動分析儀 EZ1009 Chromium Cr(VI) Analyzer
產品編號: EZ1009.XXXXXXXX
Online colorimetric analysis of dissolved Chromium Cr(VI) in water 水中溶解鉻 Cr(VI) 的線上比色分析
EZ1000 Chromium Cr(VI) Analyzers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
EZ1000 鉻 Cr(VI) 分析儀優異的精密度和準確度。精緻型設計減少試劑消耗,而長的光程長度確保高靈敏度。檢測限在低 µg/L 範圍內。
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximized uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralized water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyzer are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Chromium Cr(VI) Analyzers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyzer to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analog and digital output options
- Multiple stream analysis for up to 8 sample streams
Range:
5 - 500 µg/L Cr(VI)
5 - 500 µg/L Cr(VI)
Optional:
1 - 50 µg/L Cr(VI)
2 - 125 µg/L Cr(VI)
2.5 - 250 µg/L Cr(VI)
0.08 - 2 mg/L Cr(VI) (with internal dilution)
0.16 - 4 mg/L Cr(VI) (with internal dilution)
0.5 - 50 mg/L Cr(VI) (with internal dilution)
There are many additional options available. Please contact Hach for more details.
關鍵字 : 廢水 鉻 濃度 自動監測, 廢水 鉻 分析儀
EZ1000 Chromium Cr(VI) Analyzers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
EZ1000 鉻 Cr(VI) 分析儀優異的精密度和準確度。精緻型設計減少試劑消耗,而長的光程長度確保高靈敏度。檢測限在低 µg/L 範圍內。
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximized uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralized water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyzer are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Chromium Cr(VI) Analyzers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyzer to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analog and digital output options
- Multiple stream analysis for up to 8 sample streams
Range:
5 - 500 µg/L Cr(VI)
5 - 500 µg/L Cr(VI)
Optional:
1 - 50 µg/L Cr(VI)
2 - 125 µg/L Cr(VI)
2.5 - 250 µg/L Cr(VI)
0.08 - 2 mg/L Cr(VI) (with internal dilution)
0.16 - 4 mg/L Cr(VI) (with internal dilution)
0.5 - 50 mg/L Cr(VI) (with internal dilution)
There are many additional options available. Please contact Hach for more details.