水中總有機碳/總氮/總磷分析儀 Hach BioTector B7000 TOC/TN/TP Analyer
產品編號
A single analyzer for Carbon contamination and Nitrogen/Phosphorous nutrient levels in water 一台分析儀即可自動分析水中碳污染和氮/磷濃度

Contamination levels in water impact treatment and re-use decisions. With data on contamination plus nutrient levels water managers can make the most efficient and cost-effective decisions for treatment and reuse of important water supplies.
• Improve treatment and re-use decisions with accurate and complete water quality 透過準確和完整的水質分析數據以提升水處理,進而提供關鍵數據供水再生決策
• Reduce costs on nutrient dosing while protecting critical treatment facilities with accurate C:N:P ratios 減少投藥成本,同時以準確的 C:N:P 比率保護您重要的水處理設備
• Spend more time managing the plant and less time collecting data with a robust, industrially designed online analyzer to monitor TOC, TN, and TP parameters B7000分析儀即時監控 TOC、TN 和 TP 參數,大幅減少收集水質數據的時間,讓您能夠將時間聚焦於污水處理廠的優化管理
• Detect product loss quickly to save valuable product, and minimize risk of noncompliance by preventing excessive contamination releases to the wastewater treatment plant
The Hach TOC analyzer completes a full breakdown of each process sample to deliver trusted results.

- Improve wastewater treatment process 改善廢水處理程序
- Reduce the environmental footprint 減少環境足跡
- Protect your WWTP and WWRP 保護您的廢污水處理場設備和廢污水再生廠
- Superior reliability 卓越的可靠度

量測範圍 Range :
0 - 25 mg/L C/N/P;
0 - 50 mg/L C/N/P;
0 - 100 mg/L C/N/P;
0 - 500 mg/L C/N/P;
0 - 1000 mg/L C/N/P;
0 - 10000 mg/L C/N/P

關鍵字: 水 總有機碳 連續監測, Total Nitrogen, Total Phosphorous, 總氮, 總磷, 線上 總有機碳 即時監測 儀, online TOC, TN, TP analyzer, 廢水 TOC monitoring
產品介紹
Improve wastewater treatment process
Capture changes in water quality with a direct analysis of Total Organic Carbon (contamination), Total Nitrogen and Total Phosphorus in the most challenging samples.
 
Reduce the environmental footprint
Comprehensive information about your incoming sample composition enables improved process control. Knowing TOC + TN and TP allows you to decrease utilities usage and related costs. Optimized processes will reduce effluent environmental impact and minimize the risks of fines and reputation damage.
 
Protect your WWTP and WWRP
TOC is commonly used as a fast, reliable water analysis metric for water quality. TOC levels are often correlated to lagging water quality metrics such as Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD).
 
Superior reliability
With a certified 99.86% uptime critical process information is available when you need it most. Maintenance in most applications is done 2x per year.
 
Part Number
Range
Multi-Stream
Parameter
B4QDDF052AECAE2 0 - 25 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QGDF052AECAE2 0 - 500 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QEDF052AECAE2 0 - 50 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QFDF052AECAE2 0 - 100 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QHDF052AECAE2 0 - 1000 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QKDF052AECAE2 0 - 10000 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
 
 
Application Notes Language Size Date Edition
Industrial Discharge Monitoring before Inlet to the Municipal WWTP
DOC043.52.30250
English UK 230 KB 2016-10 Oct16
Steinbeis decides for TOC monitoring withHach BioTector B7000i
DOC043.52.30639
English UK 697 KB 2020-09 Jul20
Steinbeis decides for TOC monitoring withHach BioTector B7000i
DOC043.53.30639
English US 710 KB 2020-09 Jul20
Brochures Language Size Date Edition
Combine the organic detection power of BioTector with the sampling ease of the Venturi Sampler.
DOC063.53.30579
English US 1 MB 2019-07 Jul19
Case Studies Language Size Date Edition
C:N:P Optimisation with TOC/TN/TP Monitoring + RTC by Hach
DOC043.52.30635
English UK 569 KB 2020-10 Jul20
C:N:P Optimization with TOC/TN/TP Monitoring + RTC by Hach
DOC043.53.30635
English US 522 KB 2020-10 Jul20
Case Study: Online TOC Monitoring with BioTector - Dow chooses an innovative oxidation technology to monitor TOC/TN online
DOC043.52.30466
English UK, English US 473 KB 2019-06 Apr19
Certificates Language Size Date Edition
BioTector Case Study: Oijen, The Netherlands
DOC043.53.30428
English US 825 KB 2018-08 Jun18
Data Sheets Language Size Date Edition
BioTector Venturi Vacuum Sampler
DOC053.53.35314
English US 343 KB 2020-09 Sep20
Hach BioTector B7000 Online TOC/TN/TP Analyzer
DOC053.53.35008
English US 863 KB 2019-02 Jan19
Engineering Tender Language Size Date Edition
B7000 TOC TN CSI Specifications
MS Word Doc
English US 46 KB 2019-02 Feb19
B7000 TOC TN drawings
Download .ZIP file and extract to your computer.
File contains transmittals in format: .dwg .dxf .pdf
English US 6 MB 2019-06  
B7000 TOC TN TP CSI Specifications
MS Word Doc
English US 48 KB 2019-02 Feb19
B7000 TOC TN TP drawings
Download .ZIP file and extract to your computer.
File contains transmittals in format: .dwg .dxf .pdf
English US 5 MB 2019-06  
 
Manuals Language Size Date Edition
Advanced Configuration Manual B7000 TOC TN TP Analyzer
DOC023.52.90672
English UK 283 KB 2020-11 Ed1
Advanced Configuration, BioTector B7000 Online TOC TN Analyzer
DOC023.52.90684
English UK 262 KB 2020-11 Ed1
Information Sheet, BioTector B7000 TOC TP Analyzer
DOC333.52.90710
English UK 107 KB 2020-11 Ed1
Installation and Operation Manual, BioTector B7000 TOC TN TP
DOC023.52.90654
English UK 8 MB 2021-06 Ed2
Installation and Operation, BioTector B7000 Online TOC TN Analyzer
DOC023.52.90653
English UK 8 MB 2021-06 Ed2
Maintenance and Troubleshooting Manual, BioTector B7000 TOC TN TP Analyzer
DOC023.52.90673
English UK 2 MB 2020-11 Ed1