包裝飲料分析儀 Orbisphere 6110 Total O₂/CO₂ Package Analyzer & Installation Kit
產品編號DG6110-SYS
Total Package analyzer for Oxygen & Carbon Dioxide Measurements

The Orbisphere 6110 boasts the latest technology in final package analysis for measurements of Total Package Oxygen, Headspace Oxygen and Dissolved Oxygen; as well as dissolved Carbon Dioxide and Headspace Volume. It has been designed to meet the practical needs of both lab and at-line environments. The high-quality touch-screen facilitates measurement customisation on all types and sizes of cans or bottles, as well as providing critical information on the health of the instrument. Utilisation of this instrument has been proven to provide critical quality information of the final package, increasing process control and beverage quality.

Hach Orbisphere 6110 飲料分析儀在分析飲料時,不需從容器中移出任何產品。由於測量是在氣相狀態中進行的,因此與氧氣或二氧化碳傳感器之間沒有任何直接的液體接觸, 如此可簡化維護工作,消除諸如清洗粘著的污染物以及管道和閥門的褪色問題,進而預防污染。6110飲料包裝分析儀無需進行樣品準備, 節省耗時的水浴加熱以及晃動達到氣相平衡的工作。

無論是驗證或校正,都可透過程式設定自動運作,這樣既可節省時間,又可確保測量的準確性。

Method : Thermal Conductivity (TC) 熱傳導
Range 量測範圍 : 0 - 10 g/kg CO2

關鍵字 : 飲料線上分析儀
產品特色
Fast, Effective Operation
The 6110 delivers repeatable analysis with minimal operator intervention. The package positioning aid with laser crosshairs confirms optimal placement and the intuitive touch-screen interface ensures product sampling is completed quickly, easily, and consistently for both line operators and lab personnel. There is no sample preparation necessary for total package and head space oxygen analysis.
 
Reliable and Flexible
The 6110 Total Package analyzer operates on all types of cans and bottles due to its unique gas extraction and piercing system, resulting in reliable analysis with no container leakages. The CO2 analysis measurement provides accurate results at any temperature, without having to warm the sample. The 6110 can also compensate CO2 results for any package Nitrogen content – a perfect choice for analysis directly at the filler.
 
Gas Phase Measurement
The Hach Orbisphere 6110 analyzes beverages without removing any product from its container. The measurement takes place in the gas phase, so there is no direct liquid contact with the 6110’s sensing technology or sampling path. This reduces maintenance by eliminating hassles such as bleaching tubing and replacing valves to prevent fouling.
 
Maximize the Uptime of your 6110 Total Package analyzer
Our expert service team works in partnership with you to provide professional start-up and commissioning and regular maintenance for your 6110 Total Package analyzer to ensure it is in the optimal condition. Please speak with your local Hach representative for service offerings in your region.
 
無需備製樣品
Hach Orbisphere 6110飲料包裝分析儀無需備製樣品, 節省耗時的水浴加熱以及晃動達到氣相平衡的工作。由於無需備製樣品,這也使得6110分析儀成為過濾器直接分析的最佳選擇方案。
 
在瓶中進行分析
6110分析儀在分析飲料時,不需從容器中移出任何產品。由於測量是在氣相狀態中進行的,因此與氧氣或二氧化碳傳感器之間沒有任何直接的液體接觸, 如此可簡化維護工作,消除諸如清洗粘著的污染物以及管道和閥門的褪色問題,進而預防污染。
 
不受操作人員影響的測量結果
6110可提供更多可重複的分析,操作人員的干擾非常少。無論是驗證還是校正,都可透過編程設定自動運行,既可節省時間,又可確保測量的準確性。當放入一個樣品時,定位幫助和雷射瞄準線可確認最佳位置。接著僅需按下按鍵,儀器就可執行分析。
 
數據的完整性
使用6110的LIMS/OPC通訊協議儲存和調用測量結果可防止數據被篡改,保持數據完整性。獨立的審核追蹤亦能確保數據的可追溯性。
 
Carbon Dioxide Method Range Reagent Set(s) USEPA Compliant?
  Thermal Conductivity (TC) 0 - 10 g/kg CO2    
 