電感式水中導電度感測器 Digital Electrodeless Conductivity Sensor, Convertible Body Style, PVDF Body Material, Digital Gateway, 1m Extension Cable
產品編號:D3726E2T
PVDF, Convertible Mounting Style, 6m (20 ft) Analog Cable, Electrodeless Conductivity Sensor, includes 6120800 Digital Gateway for Connecting to sc Controller and a 6122400 1m (3 ft) Digital Extension Cable
Range 量測範圍 : 200 µS/cm - 2000 mS/cm
Accuracy 準確度 : ± 0.01 % of reading, all ranges
Sensor Type 感測器類型 : Digital
Temperature Sensor 溫度感測器 : Temperature Compensator Pt 1000 RTD
*使用Hach SC系列 digital controllers 數位控制主機進行全功能監控 – 連接後即可使用
Applications : Membrane Protection, Nutrient Monitoring, Secondary Treatment, Ultrapure Water
關鍵字 : 水中 導電度 分析儀, 導電度 線上監測, online conductivity analyzer,
Range 量測範圍 : 200 µS/cm - 2000 mS/cm
Accuracy 準確度 : ± 0.01 % of reading, all ranges
Sensor Type 感測器類型 : Digital
Temperature Sensor 溫度感測器 : Temperature Compensator Pt 1000 RTD
*使用Hach SC系列 digital controllers 數位控制主機進行全功能監控 – 連接後即可使用
Applications : Membrane Protection, Nutrient Monitoring, Secondary Treatment, Ultrapure Water
關鍵字 : 水中 導電度 分析儀, 導電度 線上監測, online conductivity analyzer,
Wide Measuring Range
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Hach’s Inductive Conductivity Sensors measure 200 up to 2,000,000 microSiemens/cm. A built-in Pt 1000 RTD compensates the measured conductivity for changes in process temperature.
Low Maintenance Design
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
The inductive sensor design eliminates polarization and electrode coating problems that commonly affect conventional contacting electrode-type conductivity sensors.
Versatile Mounting Styles
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Sensors can be installed using a choice of four mounting styles—immersion, insertion, union, and sanitary.
Principal of Operation
Inductive conductivity sensors induce a low current in a closed loop of solution, then measure the magnitude of this current to determine the solution’s conductivity. The conductivity analyzer drives Toroid A, inducing an alternating current in the solution. This current signal flows in a closed loop through the sensor bore and surrounding solution. Toroid B senses the magnitude of the induced current which is proportional to the conductance of the solution. The analyzer processes this signal and displays the corresponding reading.
Inductive conductivity sensors induce a low current in a closed loop of solution, then measure the magnitude of this current to determine the solution’s conductivity. The conductivity analyzer drives Toroid A, inducing an alternating current in the solution. This current signal flows in a closed loop through the sensor bore and surrounding solution. Toroid B senses the magnitude of the induced current which is proportional to the conductance of the solution. The analyzer processes this signal and displays the corresponding reading.
Withstands Harsh Environments
The inductive sensor is available in sanitary (CIP) flange style and convertible styles in PFA®, polypropylene, PEEK®, and PVDF material. Select sensors can withstand high pressures and temperatures.